Request Form for MkaPEB

Shattering the Monopoly: How AI-Driven Cost Optimization is Positioning Steel as the Low-Cost Leader and Unlocking a 20X Larger Market

The Strategic Amplification of Engineering Talent: Leveraging AI as a Force Multiplier in Structural Design to Drive Innovation and Growth

The First-Mover Advantage in PEB Bidding: Leveraging AI to Win More Projects with Unbeatable Speed and Precision

The First-Mover Advantage in PEB Bidding: Leveraging AI to Win More Projects with Unbeatable Speed and Precision

The First-Mover Advantage in PEB Bidding: Leveraging AI to Win More Projects with Unbeatable Speed and Precision

The Strategic Amplification of Engineering Talent: Leveraging AI as a Force Multiplier in Structural Design to Drive Innovation and Growth

Shattering the Monopoly: How AI-Driven Cost Optimization is Positioning Steel as the Low-Cost Leader and Unlocking a 20X Larger Market

The First-Mover Advantage in PEB Bidding: Leveraging AI to Win More Projects with Unbeatable Speed and Precision

Snow Load
Wind Load
Seismic Information
Snow Load Code USA: ASCE-07-22
Risk Category II
Snow Surface Type B (see Section 26.7)
Exposure Type Fully Exposed
Thermal Condition Unheated structures, open-air structures, structures kept just above freezing [40 to 50 °F (4 to 10 °C)], and other structures with cold, ventilated roofs meeting the minimum requirements of the applicable energy code
Winter Wind Parameter, W2 0.0
Ground Snow Load 30 lb/ft² | 1.437 kN/m²
Flat Roof Snow Load 22.68 psf | 1.086 kN/m²

Wind Load Code USA: ASCE-07-22
Main Wind Force Resisting System Chapter 27
Components And Claddings Chapter 30
Building Class I
Wind Exposure For buildings or other structures with a mean roof height ≤ 30 ft (9.1 m): Exposure Category B applies where Surface Roughness B prevails for a distance > 1,500 ft (457 m).
For buildings > 30 ft (9.1 m): Exposure B applies where Surface Roughness B prevails for a distance > 2,600 ft (792 m) or 20 times the building height, whichever is greater. [ASCE 7-22]
Topographic Type 2D Ridge
Kzt 1.00
In Hurricane Prone FALSE
Wind Speed 85 mph
Enclosure Class Enclosed buildings
Internal Pressure Coefficient Cpi+ 0.18
Internal Pressure Coefficient Cpi- 0.18

Seismic Design Code USA: ASCE-07-22
Longitude 34.05354
Latitude -118.24529
Ss 2.442
S1 0.857
Pga 0.924
Pgv 0.924
Ground Type C
Ground Type Description Very dense sand or hard clay
Structural System C04: Steel ordinary moment frames
Reduction Factor (R) 3.5
Importance Factor (I) 1
Live Load Factor (n) 0.3

Snow Load Table

Snow Load

Snow Load Code USA: ASCE-07-22
Risk Category II
Snow Surface Type B (see Section 26.7)
Exposure Type Fully Exposed
Thermal Condition Unheated structures, open-air structures, structures kept just above freezing [40 to 50 °F (4 to 10 °C)], and other structures with cold, ventilated roofs meeting the minimum requirements of the applicable energy code
Winter Wind Parameter, W2 0.0
Ground Snow Load 30 lb/ft² | 1.437 kN/m²
Flat Roof Snow Load 22.68 psf | 1.086 kN/m²
Wind Load Table

Wind Load

Wind Load Code USA: ASCE-07-22
Main Wind Force Resisting System Chapter 27
Components And Claddings Chapter 30
Building Class I
Wind Exposure For buildings or other structures with a mean roof height ≤ 30 ft (9.1 m): Exposure Category B applies where Surface Roughness B prevails for a distance > 1,500 ft (457 m).
For buildings > 30 ft (9.1 m): Exposure B applies where Surface Roughness B prevails for a distance > 2,600 ft (792 m) or 20 times the building height, whichever is greater. [ASCE 7-22]
Topographic Type 2D Ridge
Kzt 1.00
In Hurricane Prone FALSE
Wind Speed 85 mph
Enclosure Class Enclosed buildings
Internal Pressure Coefficient Cpi+ 0.18
Internal Pressure Coefficient Cpi- 0.18
Seismic Information Table

Seismic Information

Seismic Design Code USA: ASCE-07-22
Longitude 34.05354
Latitude -118.24529
Ss 2.442
S1 0.857
Pga 0.924
Pgv 0.924
Ground Type C
Ground Type Description Very dense sand or hard clay
Structural System C04: Steel ordinary moment frames
Reduction Factor (R) 3.5
Importance Factor (I) 1
Live Load Factor (n) 0.3

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/CelikYapiModeliOnDegerlendirmesi.pdf"]

[/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/CelikYapiyaEtkiyenYukleri.pdf"]

[/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/CelikYapilardaYukBirlesimleri.pdf"]

[/dflip]

 

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/GeoteknikRaporVeTemelTasarimi.pdf"]

[/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/ServiceContractDE.pdf"]

[/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/ServiceContractTR.pdf" ]

[/dflip]

 

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/07/ServiceContractEN.pdf"]

[/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/06/General-Terms-And-ConditionsDE.pdf"] [/dflip]

[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/06/General-Terms-And-ConditionsEN.pdf"]

[/dflip]

 
[dflip source="https://www.mkapeb.com/wp-content/uploads/2024/06/General-Terms-And-ConditionsTR.pdf"] [/dflip]

Please choose

Product(s)

Please review the Terms,Conditions and Privacy Policy

12 + 5 =